Measurement of up to five gases.
Highly accurate measurements.
No optical alignment required.
Filed-proven technologies.
No routine maintenance required.
![]()
The HORIBA XS analyzer utilizes chemiluminescence and mangetopneumatic as well as cross-flow modulated no-dispersive ifrared (NDIR) technologies providing highly accurate measurement for up to five gasses plus system control, yet requiring no routine maintenance nor optical alignment.
The XS analyzer features specialized designs such as the optimized path length and high sensitivity detector that give precision measurements with a sample flow rate of less than one liter per minute.
The XS analyzer automatically initiates system calibration at intervals predefined by the user. The easy-to-read display can show concentrations for any of up to five gasses, or display averages or diluent-corrected values.
A micro-processor provides true computerized control plus self-diagnostics that allow the user to easily determine the source of an alarm or caution signal displayed on the front panel.
| Gas | Range (min.) | Range (max.) |
|---|---|---|
NOx |
0-100 ppm | 0-5000 ppm |
SO2 |
0-50 ppm | 0-5000 ppm |
CO |
0-50 ppm | 0-5000 ppm |
CO2 |
0-5% | 0-50% |
O2 |
0-10% | 0-25% |
Zero Drift
Ranges ≥200 ppm: ±1.0% (full scale) per 7 days
Ranges ≤200 ppm and O2 : ±2.0% (full scale) per 7 days
Repeatability
Ranges ≥200 ppm: ±0.5% (full scale)
Ranges ≤200 ppm and O2: ±1.0% (full scale)